001437874 000__ 03293cam\a2200517\a\4500 001437874 001__ 1437874 001437874 003__ OCoLC 001437874 005__ 20230309004237.0 001437874 006__ m\\\\\o\\d\\\\\\\\ 001437874 007__ cr\un\nnnunnun 001437874 008__ 210702s2021\\\\si\\\\\\o\\\\\000\0\eng\d 001437874 019__ $$a1260343510$$a1266814951 001437874 020__ $$a9789811604355$$q(electronic bk.) 001437874 020__ $$a9811604355$$q(electronic bk.) 001437874 020__ $$z9811604347 001437874 020__ $$z9789811604348 001437874 0247_ $$a10.1007/978-981-16-0435-5$$2doi 001437874 035__ $$aSP(OCoLC)1258674648 001437874 040__ $$aYDX$$beng$$epn$$cYDX$$dGW5XE$$dEBLCP$$dOCLCO$$dOCLCF$$dDCT$$dUKAHL$$dOCLCO$$dOCLCQ$$dN$T$$dCOM$$dFAU$$dCASUM$$dOCLCQ 001437874 049__ $$aISEA 001437874 050_4 $$aRE451 001437874 08204 $$a617.7/42059$$223 001437874 24500 $$aDouble-pass optical quality analysis for the clinical practice of cataract /$$cA-Yong Yu, editor. 001437874 260__ $$aSingapore :$$bSpringer,$$c2021. 001437874 300__ $$a1 online resource 001437874 336__ $$atext$$btxt$$2rdacontent 001437874 337__ $$acomputer$$bc$$2rdamedia 001437874 338__ $$aonline resource$$bcr$$2rdacarrier 001437874 347__ $$atext file 001437874 347__ $$bPDF 001437874 5050_ $$aVisual quality in the age of refractive cataract surgery -- Analysis of objective visual quality based on Double-pass technology -- Clinical significance of the main parameters of Double-pass Optical Quality Analysis System -- Acquisition mode and operation procedure of Double-pass Optical Quality Analysis System -- Clinical application of objective evaluation of tear film optical quality -- Objective classification of cataract -- Timing of cataract surgery -- Prediction of the visual quality after cataract surgery -- Doctor-patient Communication -- Comparison of cataract treatment methods -- Optimal treatment timing for posterior capsule opacification. 001437874 506__ $$aAccess limited to authorized users. 001437874 520__ $$aThis book introduces the principle, main parameters, acquisition mode and operation procedure of Optical Quality Analysis System II (OQAS II) based on double-pass technology. OQAS II is increasingly used in the diagnosis and assessment of ocular diseases, especially for cataract. In this book, the clinical practice of OQAS II in the field of refractive cataract surgery is emphasized, including the preoperative/postoperative evaluation of visual quality, the timing of cataract surgery, the prediction of the visual quality after cataract surgery and doctor-patient communication. We hope the book provides a reference for the clinical application of the OQAS II in the field of cataract and helps to form the worldwide standard specification to a certain extent. 001437874 588__ $$aOnline resource; title from PDF title page (SpringerLink, viewed July 20, 2021). 001437874 650_0 $$aCataract$$xSurgery. 001437874 650_6 $$aCataracte (Ophtalmologie)$$xChirurgie. 001437874 655_7 $$aLlibres electrònics.$$2thub 001437874 655_0 $$aElectronic books. 001437874 7001_ $$aYu, A-Yong,$$eeditor. 001437874 77608 $$iPrint version:$$tDouble-pass optical quality analysis for the clinical practice of cataract.$$dSingapore : Springer, 2021$$z9811604347$$z9789811604348$$w(OCoLC)1233166877 001437874 852__ $$bebk 001437874 85640 $$3Springer Nature$$uhttps://univsouthin.idm.oclc.org/login?url=https://link.springer.com/10.1007/978-981-16-0435-5$$zOnline Access$$91397441.1 001437874 909CO $$ooai:library.usi.edu:1437874$$pGLOBAL_SET 001437874 980__ $$aBIB 001437874 980__ $$aEBOOK 001437874 982__ $$aEbook 001437874 983__ $$aOnline 001437874 994__ $$a92$$bISE