TY - GEN N2 - This book introduces the origin of biomedical signals and the operating principles behind them and presents the characteristics of common biomedical signals for subsequent signal measurement and judgment. Since biomedical signals are captured by wearable devices, sensor devices, or implanted devices, these devices are all battery-powered to maintain long working time. We hope to reduce their power consumption to extend service life, especially for implantable devices, because battery replacement can only be done through surgery. Therefore, we must understand how to design low-voltage low-power integrated circuits. Provides necessary background information on biomedical signals and proceeds with design considerations for low supply voltage analog circuits; Describes design techniques for not only frequency synthesizers and ADCs, but also the ultra-low voltage design techniques of these circuits; Demonstrates examples to overcome typical design challenges. DO - 10.1007/978-3-030-88845-9 DO - doi AB - This book introduces the origin of biomedical signals and the operating principles behind them and presents the characteristics of common biomedical signals for subsequent signal measurement and judgment. Since biomedical signals are captured by wearable devices, sensor devices, or implanted devices, these devices are all battery-powered to maintain long working time. We hope to reduce their power consumption to extend service life, especially for implantable devices, because battery replacement can only be done through surgery. Therefore, we must understand how to design low-voltage low-power integrated circuits. Provides necessary background information on biomedical signals and proceeds with design considerations for low supply voltage analog circuits; Describes design techniques for not only frequency synthesizers and ADCs, but also the ultra-low voltage design techniques of these circuits; Demonstrates examples to overcome typical design challenges. T1 - Ultra-low-voltage frequency synthesizer and successive-approximation analog-to-digital converter for biomedical applications / AU - Hung, Chung-Chih, AU - Wang, Shih-Hsing, CN - R857.B54 ID - 1443183 KW - Biosensors. KW - Frequency synthesizers. KW - Analog-to-digital converters. KW - Biocapteurs. KW - Synthétiseurs de fréquence. KW - Convertisseurs analogique-numérique. SN - 9783030888459 SN - 3030888452 TI - Ultra-low-voltage frequency synthesizer and successive-approximation analog-to-digital converter for biomedical applications / LK - https://univsouthin.idm.oclc.org/login?url=https://link.springer.com/10.1007/978-3-030-88845-9 UR - https://univsouthin.idm.oclc.org/login?url=https://link.springer.com/10.1007/978-3-030-88845-9 ER -