Go to main content
Formats
Format
BibTeX
MARCXML
TextMARC
MARC
DublinCore
EndNote
NLM
RefWorks
RIS
Cite
Citation

Linked e-resources

Details

Intro
Preface
Organization
Contents
Influence of Electrode System Geometry on Efficiency of Particle Collection of a Compact Electrostatic Precipitator for Small Scale Biomass Combustion
1 Introduction
2 Design of Electrostatic Precipitator
3 Test of Pilot ESP with Wood-Chips Boiler
4 Test of Pilot ESP with Wood-Pellets Boiler
5 Test of Pilot ESP with Wood-Logs Stove
6 Conclusions
References
Novel Compact Electrostatic Precipitators for Small-Scale Biomass Combustion Facilities
1 Introduction
2 Design and Operation of a Compact ESP

3 Results of Experimental Study of the Compact ESP
4 Observations and Discussion
5 Compact ESPs for Variable Gas Flow Rates
6 Conclusions
References
Collection of Carbon Particles in Diesel Exhaust Gas Using Intermittent Dielectric Barrier Discharge
1 Introduction
2 Experimental Setup and Method
3 Results and Discussion
4 Conclusions
References
Combustion of Carbon Black Collected on an ESP by Microwaves Irradiation Using Slit Plate
1 Introduction
2 Simulation
3 Experiment
4 Results and Discussion
4.1 Simulation Result
4.2 Microwave Absorption

4.3 Effect on Temperature of Dust
4.4 Concentration of Carbon Monoxide
4.5 Combustion Rate
4.6 Effect of Input Power on the Combustion Rate
5 Summary
References
Study of Effective Particle Charging Regions in a Corona Discharge in an Electrostatic Precipitator
1 Introduction
2 Assumed Model and Previous Research
3 Calculational Model
4 Results and Discussion
4.1 Diffusion Charging and Field Charging
4.2 Increased Discharge Power with Constant Voltage or Constant Current
4.3 Effective Charge Region
5 Concluding Remarks
References

Different Types of Dust Resistivity
1 Introduction
2 State of Knowledge
2.1 Measurement of Dust Resistivity - State of the Art
2.2 Non-ohmic Characteristics of Dust Resistivity - Dielectric Dust Type
2.3 The Concept of Pulsed Corona Operation
2.4 The Concept of Low Frequency AC Corona Operation
2.5 The Concept of 3 Phase Transformer/Rectifier Sets
3 Recent Experience with Precipitation of Ore Sintering Dust
3.1 Observations with Industrial ESPs for Iron Ore Sintering Dust
3.2 IOS Dust Resistivity Showing Varistor Characteristics

4 Discussion: Dust Resistivity Type and Back Corona Countermeasures
5 Conclusions
References
Effect of Electrostatic Precipitation and Agglomeration of Particles on Bag Filter Regeneration
1 Introduction
2 Hybrid Electrostatic Filtration System
3 Experimental Methodology
4 Measurements
4.1 Electrostatic Precipitation and Agglomeration Effect on Particle Penetration
4.2 Electric Charge of Fly Ash Particles
4.3 Effect of Electrostatic Precipitator and Agglomerator on Filtration and Bag Filter Regeneration
5 Discussion
6 Conclusions
References

Browse Subjects

Show more subjects...

Statistics

from
to
Export