Linked e-resources

Details

Preface; Contents; 1 Introduction; 1.1 Implanted Bio-devices; 1.2 Present and Future; 1.2.1 Rodents in Research; 1.2.2 Modelling Biomedical Systems; 1.3 Integrated Biomedical Systems; 1.4 Reach of Care Extension; 1.5 Motivation and Background; References; 2 Implantable Monitoring System for Rodents; 2.1 Bio-monitoring Systems; 2.2 System Overview and Specifications; 2.2.1 Rodents and Housing; 2.2.2 Multi-sensor Systems; 2.3 State of the Art; 2.4 Challenges and Objectives; References; 3 Short-Range Remote Powering of Implantable Sensor System; 3.1 Power Sources for Remotely Powered Systems.

3.1.1 Use of Kinetic Energy3.1.2 Use of Thermal Energy; 3.1.3 Use of Light Energy; 3.1.4 Use of Bio-fuel; 3.1.5 Use of Radio Frequency; 3.1.6 Use of Ultrasound; 3.2 Wireless Power Transfer; 3.2.1 Remote Powering Link; 3.2.1.1 Optimization of Remote Powering Link; 3.2.1.2 Misalignment Analysis; 3.2.1.3 Optimal Power Transfer Frequency; 3.2.1.4 Optimized Remote Powering Link for Freely Moving Animals; 3.2.2 Link Drivers; 3.2.2.1 Modeling of Remote Powering Link; 3.2.2.2 Class-C Power Amplifier; 3.2.2.3 Class-D Power Amplifier; 3.2.2.4 Comparison of Class-C and Class-D Amplifiers.

3.2.2.5 Class-E Power Amplifier3.3 Implantable Remote Powering Electronics; 3.3.1 Rectifier; 3.3.2 Voltage Regulator; 3.3.3 Reference Voltage Generation; 3.3.4 Power on Reset; 3.3.5 Dynamic Power Adaptation and Power Feedback Loop; References; 4 Wireless Communication; 4.1 Communication Scenarios; 4.2 A FoM to Compare the Effect of Communications on Remotely Powered Systems; 4.2.1 Remote Powering; 4.2.1.1 Power Consumption; 4.2.1.2 Link Parameters (Q, k, fo); 4.2.2 Communication; 4.2.2.1 Modulation Methods; 4.2.2.2 Communication Parameters (fc, DRmax, Dsend, BER).

4.2.3 Powering During Communication4.2.3.1 Communication Rate (CR); 4.2.3.2 Modulation Rate (MR); 4.2.3.3 Powering Index (pi); 4.2.4 Figure-of-Merit; 4.3 Downlink Communication; 4.3.1 ASK Demodulator; 4.3.1.1 PPM Demodulator; 4.4 Uplink Communication; 4.4.1 Low-Power OOK Transmitter; 4.4.2 Custom Designed Receiver; References; 5 Intelligent Remote Powering System; 5.1 Introduction; 5.2 Intelligent Mouse Cage for Remotely Powered Implantable Systems; 5.2.1 Controller Unit; 5.2.2 Realization and Verification; 5.3 Servo-Controlled Remote Powering and Monitoring System.

5.3.1 Realization and Verification5.3.2 Discussion; References; 6 System Integration and Packaging; 6.1 System Integration; 6.2 Packaging and Assembly of Micro-system; References; 7 Conclusion; 7.1 Outlook; Appendix A Locator System for Implantable Devices; Glossary.

Browse Subjects

Show more subjects...

Statistics

from
to
Export