Foreword; Preface; Contents; Contributors; Part I: Introduction or Principles of Functional Assessment; Chapter 1: Assessing Patient Suitability andßOutcome Measures inßVision Restoration Trials; Developing anßInternational Consensus onßtheßMeasurement andßReporting ofßPatient Outcomes: TheßHarmonization ofßOutcomes andßVision Endpoints inßVision Restoration Trials (HOVER) Taskforce; Advice toßtheßPracticing Ophthalmologist: How toßTest andßAdvise Patients Interested inßRestoration Therapies atßPresent; References; Chapter 2: Functional Assessment ofßArtificial Vision; Introduction.

Standardisation Forced Choice Testing; Efficient Testing Algorithms andßScoring Methods; Psychometric Properties ofßFunctional Vision Tests; Basic Visual Function Tests; Light Perception; Spatial Resolution; Activities ofßDaily Living; Object Recognition; Picture Recognition; Navigation Ability; Multimodal Sensory Integration; Conclusions; References; Chapter 3: Patient-Reported Outcomes (PRO) forßProsthetic Vision; Introduction; Basic Psychometric Concepts; Rasch Analysis; Precision ofßItem andßPerson Measure Estimates; Subscales, Visual Domains, Visual Aspects.

Application toßProsthetic VisionReferences; Chapter 4: Prospects andßLimitations ofßSpatial Resolution; Which Spatial Resolution Should BeßTargeted byßVisual Prosthesis?; Reading; Visuo-motor Coordination; Whole Body Mobility; Synthesis; From Theory toßReality; Conclusion andßFinal Thoughts; References; Part II: Retinal Approaches; Chapter 5: Argus® II Retinal Prosthesis System; Principal Idea; Indication; Technical Description; Surgical Methods; Full Clinical Study; Device Development History; Argus I; Argus® II; Patients; Adverse Events; Functional Ouctomes.

Visual Function Orientation andßMobilitity Tests; Activities ofßDaily Living; Future Directions; References; Chapter 6: The Subretinal Implant ALPHA: Implantation andßFunctional Results; Introduction: Principal Concept andßSteps ofßDevelopment; Technical Description; Indication forßCertain Forms ofßBlindness; Who Can Benefit fromßtheßSubretinal Implant toßWhat Extent?; Surgical Procedure forßSubretinal Implants; Replacement ofßImplants; Clinical Study Results; Safety; Conclusion; References; Chapter 7: The Boston Retinal Implant; Overview; Background; Device Requirements.

The Boston Retinal Implant Wireless Power andßData; Custom Integrated Circuit Design; Microfabricated Thin-Film Multi-electrode Array; Hermetic Retinal Implant Packaging; Current Status andßFuture Directions; References; Chapter 8: Pixium Vision: First Clinical Results andßInnovative Developments; Introduction; IRISTM System Description; External Components; Implant; Surgical Method; The Clinical Trial; Acute Clinical Trail; Chronic Clinical Trial; Future Technologies; Conclusions; References.

Browse Subjects

Show more subjects...