Linked e-resources
Details
Table of Contents
Preface; Acknowledgements; Contents; About the Author; Introduction; 1 The Event Defined; 2 Facts Regarding Typical Events; References; 3 Localized Events; Typical Areas of Localized Events; Typical Reasons for Localized Events; Localized Small Explosive Events; References; 4 Who Is At Fault; Design Versus Manufacturing Problem; 5 High Current PCB Connections; How to Determine if Excessive I2R Heating Is Within a Connector, a Nearby Solder Connection, or a Trace; 6 Liquid, Moisture and Electronics; Reference; 7 The Ugly Process; Manifestations of the Ugly Process
Liquid, Moisture on a Coated PCBReference; 8 Liability Related Electronic Control Deficiencies; References; 9 Localized Event Explained- Charred Hole; Visual Artifact; Evaluation; Cause; Time to Failure; Problem Resolution; 10 Localized Event Explained-Partially Charred Surface; Visual Artifact; Evaluation; Cause; Time to Failure; Problem Resolution; Reference; 11 Localized Event Explained-Scorched FR-4 with no Missing Weave; Visual Artifact; Evaluation; Three Possibilities; Cause; Time to Failure; Problem Resolution; 12 Localized Event Explained-Scorched FR-4 with Missing Weave
Visual ArtifactEvaluation; Time to Failure; Problem Resolution; 13 PCB Smoke and Fire Damage for Power Levels Below 5 Watts; Where Do We Start?; Reference; 14 Bench Experiments; For Each Experiment Conducted; Sample Construction; Sources of Variation; Experiment #1; Experiment #2; Experiment #3; Experiment #4; Experiment #5; Experiment #6; Experiment #7; Experiment #8; Experiment #9a; Experiment #9b; Experiment #10; References; 15 Summary of Experiments; Appendix
Liquid, Moisture on a Coated PCBReference; 8 Liability Related Electronic Control Deficiencies; References; 9 Localized Event Explained- Charred Hole; Visual Artifact; Evaluation; Cause; Time to Failure; Problem Resolution; 10 Localized Event Explained-Partially Charred Surface; Visual Artifact; Evaluation; Cause; Time to Failure; Problem Resolution; Reference; 11 Localized Event Explained-Scorched FR-4 with no Missing Weave; Visual Artifact; Evaluation; Three Possibilities; Cause; Time to Failure; Problem Resolution; 12 Localized Event Explained-Scorched FR-4 with Missing Weave
Visual ArtifactEvaluation; Time to Failure; Problem Resolution; 13 PCB Smoke and Fire Damage for Power Levels Below 5 Watts; Where Do We Start?; Reference; 14 Bench Experiments; For Each Experiment Conducted; Sample Construction; Sources of Variation; Experiment #1; Experiment #2; Experiment #3; Experiment #4; Experiment #5; Experiment #6; Experiment #7; Experiment #8; Experiment #9a; Experiment #9b; Experiment #10; References; 15 Summary of Experiments; Appendix