000823275 000__ 04970cam\a2200577Ii\4500 000823275 001__ 823275 000823275 005__ 20230306144018.0 000823275 006__ m\\\\\o\\d\\\\\\\\ 000823275 007__ cr\cn\nnnunnun 000823275 008__ 170801s2017\\\\si\a\\\\ob\\\\001\0\eng\d 000823275 019__ $$a999407805$$a1000033317 000823275 020__ $$a9789811042775$$q(electronic book) 000823275 020__ $$a9811042772$$q(electronic book) 000823275 020__ $$z9789811042768 000823275 020__ $$z9811042764 000823275 035__ $$aSP(OCoLC)ocn997400483 000823275 035__ $$aSP(OCoLC)997400483$$z(OCoLC)999407805$$z(OCoLC)1000033317 000823275 040__ $$aN$T$$beng$$erda$$epn$$cN$T$$dGW5XE$$dEBLCP$$dYDX$$dN$T$$dOCLCF$$dUAB$$dU3W$$dCAUOI 000823275 049__ $$aISEA 000823275 050_4 $$aTK7872.I65 000823275 08204 $$a621.3815/322$$223 000823275 24500 $$aControl techniques for LCL-type grid-connected inverters /$$cXinbo Ruan, Xuehua Wang, Donghua Pan, Dongsheng Yang, Weiwei Li, Chenlei Bao. 000823275 264_1 $$aSingapore :$$bSpringer,$$c2017. 000823275 300__ $$a1 online resource (xx, 307 pages) :$$billustrations. 000823275 336__ $$atext$$btxt$$2rdacontent 000823275 337__ $$acomputer$$bc$$2rdamedia 000823275 338__ $$aonline resource$$bcr$$2rdacarrier 000823275 4901_ $$aCPSS power electronics series,$$x2520-8853 000823275 504__ $$aIncludes bibliographical references and index. 000823275 5050_ $$aPreface; Acknowledgements; Contents; About the Authors; Abbreviations; 1 Introduction; Abstract; 1.1 Energy Situation and Environmental Issues; 1.2 Renewable Energy-Based Distributed Power Generation System; 1.3 Key Issues of LCL-Type Grid-Connected Inverters; 1.3.1 Design and Magnetic Integration of LCL Filter; 1.3.2 Resonance Damping Methods of LCL Filter; 1.3.3 Controller Design of Grid-Connected Inverters; 1.3.3.1 Classification of Control Schemes; 1.3.3.2 Closed-Loop Design Targets; 1.3.3.3 Grid Current Regulator; 1.3.4 Effects of Control Delay and the Compensation Methods 000823275 5058_ $$a1.3.4.1 Control Delay Effects1.3.4.2 Control Delay Compensation Methods; 1.3.5 Suppression of Grid Current Distortion Caused by Grid Voltage Harmonics; 1.3.5.1 Suppression of Grid Current Distortion and Unbalance Caused by Grid Voltage; 1.3.5.2 Suppression of the Grid Current Reference Error; 1.3.6 Grid-Impedance Effects on System Stability and the Improvement Methods; 1.4 Summary; References; 2 Design of LCL Filter; Abstract; 2.1 PWM for Single-Phase Full-Bridge Grid-Connected Inverter; 2.1.1 Bipolar SPWM; 2.1.2 Unipolar SPWM; 2.2 PWM for Three-Phase Grid-Connected Inverter; 2.2.1 SPWM 000823275 5058_ $$a2.2.2 Harmonic Injection SPWM Control2.3 LCL Filter Design; 2.3.1 Design of the Inverter-Side Inductor; 2.3.1.1 Single-Phase Full Bridge Grid-Connected Inverter; 2.3.1.2 Three-Phase Grid-Connected Inverter; 2.3.2 Filter Capacitor Design; 2.3.3 Grid-Side Inductor Design; 2.4 Design Examples for LCL Filter; 2.4.1 Single-Phase LCL Filter; 2.4.2 Three-Phase LCL Filter; 2.5 Summary; References; 3 Magnetic Integration of LCL Filters; Abstract; 3.1 Magnetic Integration of LCL Filters; 3.1.1 Magnetic Integration of Single-Phase LCL Filter; 3.1.2 Magnetic Integration of Three-Phase LCL Filter 000823275 5058_ $$a3.2 Coupling Effect on Attenuating Ability of LCL Filter3.2.1 Magnetic Circuit of Integrated Inductors; 3.2.2 Characteristics of LCL Filter with Coupled Inductors; 3.3 Design Examples; 3.3.1 Magnetics Design for Single-Phase LCL Filter; 3.3.2 Magnetics Design for Three-Phase LCL Filter; 3.4 Experimental Verification; 3.4.1 Experimental Results for Single-Phase LCL Filter; 3.4.2 Experimental Results for Three-Phase LCL Filter; 3.5 Summary; References; 4 Resonance Damping Methods of LCL Filter; Abstract; 4.1 Resonance Hazard of LCL Filter; 4.2 Passive-Damping Solutions 000823275 5058_ $$a4.2.1 Basic Passive Damping4.2.2 Improved Passive Damping; 4.3 Active-Damping Solutions; 4.3.1 State-Variable-Feedback Active Damping; 4.3.2 Notch-Filter-Based Active Damping; 4.4 Summary; References; 5 Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping; Abstract; 5.1 Modeling LCL-Type Grid-Connected Inverter; 5.2 Frequency Responses of Capacitor-Current-Feedback Active-Damping and PI Regulator; 5.3 Constraints for Controller Parameters; 5.3.1 Requirement of Steady-State Error 000823275 506__ $$aAccess limited to authorized users. 000823275 588__ $$aOnline resource; title from PDF title page (SpringerLink, viewed August 3, 2017). 000823275 650_0 $$aElectric inverters. 000823275 650_0 $$aDistributed generation of electric power. 000823275 650_0 $$aRenewable energy sources. 000823275 7001_ $$aRuan, Xinbo,$$eauthor. 000823275 7001_ $$aWang, Xuehua,$$eauthor. 000823275 7001_ $$aPan, Donghua,$$eauthor. 000823275 7001_ $$aYang, Dongsheng,$$eauthor. 000823275 7001_ $$aLi, Weiwei,$$eauthor. 000823275 7001_ $$aBao, Chenlei,$$eauthor. 000823275 77608 $$iPrint version: $$z9811042764$$z9789811042768$$w(OCoLC)973303565 000823275 830_0 $$aCPSS power electronics series. 000823275 852__ $$bebk 000823275 85640 $$3SpringerLink$$uhttps://univsouthin.idm.oclc.org/login?url=http://link.springer.com/10.1007/978-981-10-4277-5$$zOnline Access$$91397441.1 000823275 909CO $$ooai:library.usi.edu:823275$$pGLOBAL_SET 000823275 980__ $$aEBOOK 000823275 980__ $$aBIB 000823275 982__ $$aEbook 000823275 983__ $$aOnline 000823275 994__ $$a92$$bISE