000827211 000__ 05077cam\a2200553Ii\4500 000827211 001__ 827211 000827211 005__ 20230306144603.0 000827211 006__ m\\\\\o\\d\\\\\\\\ 000827211 007__ cr\cn\nnnunnun 000827211 008__ 180403s2018\\\\si\\\\\\o\\\\\100\0\eng\d 000827211 019__ $$a1033666618$$a1034555550 000827211 020__ $$a9789811078590$$q(electronic book) 000827211 020__ $$a9811078599$$q(electronic book) 000827211 020__ $$z9789811078583 000827211 0247_ $$a10.1007/978-981-10-7859-0$$2doi 000827211 035__ $$aSP(OCoLC)on1030303073 000827211 035__ $$aSP(OCoLC)1030303073$$z(OCoLC)1033666618$$z(OCoLC)1034555550 000827211 040__ $$aN$T$$beng$$erda$$epn$$cN$T$$dGW5XE$$dN$T$$dYDX$$dOCLCF$$dMERER$$dUPM$$dEBLCP 000827211 049__ $$aISEA 000827211 050_4 $$aR895.A2 000827211 08204 $$a616.07/575$$223 000827211 1112_ $$aInternational Conference on Radiation Safety & Security in Healthcare Services$$n(3rd :$$d2017 :$$cPenang, Malaysia) 000827211 24510 $$a3rd International Conference on Radiation Safety & Security in Healthcare Services :$$bproceedings of the Thirs, ICRSSHS, Dewan Budaya USM, Penang, Malaysia /$$cR. Zainon, editor. 000827211 2463_ $$aICRSSHS 000827211 264_1 $$aSingapore :$$bSpringer,$$c2018. 000827211 300__ $$a1 online resource. 000827211 336__ $$atext$$btxt$$2rdacontent 000827211 337__ $$acomputer$$bc$$2rdamedia 000827211 338__ $$aonline resource$$bcr$$2rdacarrier 000827211 347__ $$atext file$$bPDF$$2rda 000827211 4901_ $$aLecture notes in bioengineering 000827211 500__ $$aInternational conference proceedings. 000827211 5050_ $$aIntro; Preface; Contents; The Influence of Pitch Factor in Reducing Computed Tomography Head Dose Exposure: Single-Centre Trials; 1 Introduction; 2 Methodology; 2.1 CT System; 2.2 CT Dose Quantities; 2.3 Data Collection; 3 Results; 4 Discussion; 5 Conclusion; References; Image Quality Evaluation in Contrast Agents Computed Tomography Imaging; 1 Introduction; 2 Materials and Methods; 2.1 Preparation of Phantom for CT Imaging; 2.2 CT Scanning Parameters and Image Analysis; 3 Results and Discussion; 4 Conclusion; References 000827211 5058_ $$aStudy on Different Method to Determine the Individual Diameter for Size-Specific Dose Estimates (SSDE) in Adult Patients1 Introduction; 2 Method; 2.1 Survey and Determination of Individual Diameter for Adult Abdomen; 2.2 Calculation of Radiation Dose Based on SSDE; 2.3 Comparative Study of Displayed Dose Versus SSDE-Calculated Dose; 3 Results; 3.1 Survey and Determination on Effective Diameter of Adult Abdomen; 3.2 SSDE-Calculated Dose, CTDIvol; 3.3 Comparative Study of Displayed CTDIvol Versus SSDE-Calculated CTDIvol; 4 Discussion; 5 Conclusions; References 000827211 5058_ $$aInvestigation of Patient Dose Received During Digital Dental Radiography and Comparison with International Diagnostic Reference Level (DRL)1 Introduction; 2 Methods; 2.1 Survey on Local Patient Dose Data; 2.2 Comparative Study of Local Dose with the International DRLs; 3 Results and Discussion; 3.1 Survey on Local Patient Dose Data; 3.2 Comparative Study of Local Dose with the International DRLs; 4 Conclusion; References; Evaluation of Metal Artifacts from Stainless Steel and Titanium Alloy Orthopedic Screw in Computed Tomography Imaging; 1 Introduction; 2 Materials and Methods 000827211 5058_ $$a2.1 Phantom Fabrication and Setup2.2 CT Parameters; 2.3 Image Analysis; 2.4 SNR Measurements; 2.5 Statistical Analysis; 3 Results and Discussions; 3.1 Single-Energy and Dual-Energy CT; 3.2 Artifact Severity of Stainless Steel and Titanium Alloy; 3.3 Effect of Slice Thickness on CT Images; 3.4 The SNR at Different Slice Thickness and Pitch; 4 Conclusion; References; Occupational Dose in Nuclear Medicine Department; Hospital Kuala Lumpur Experience; 1 Introduction; 1.1 Optically Stimulated Luminescence; 1.2 Radio-Photoluminescence; 2 Methodology; 2.1 Study Design; 2.2 Subjects 000827211 5058_ $$a2.3 Dosimetry Procedure3 Result and Discussion; 4 Conclusion; References; Determination of Mass Attenuation Coefficient of Paraffin Wax and Sodium Chloride as Tissue Equivalent Materials; 1 Introduction; 2 Experimental Design; 3 Result and Discussion; 4 Conclusion; References; Study on Effectiveness of Physical Protection and Security Management of Radioactive Sources in Medical Institutions in Malaysia; 1 Introduction; 1.1 Global Threat Reduction Initiatives-GTRI; 1.2 Regional Security of Radioactive Sources (RSRS); 1.3 Nuclear Security Summit (NSS) 000827211 506__ $$aAccess limited to authorized users. 000827211 520__ $$aThis book presents the proceedings of the 3rd International Conference on Radiation Safety & Security in Healthcare Services. The conference was held at Universiti Sains Malaysia in Penang on 19th–20th August 2017. 000827211 588__ $$aOnline resource; title from PDF title page (SpringerLink, viewed April 3, 2018). 000827211 650_0 $$aNuclear medicine$$vCongresses. 000827211 650_0 $$aRadioactivity$$xSafety measures$$vCongresses. 000827211 7001_ $$aZainon, R.,$$eeditor. 000827211 77608 $$iPrint version: $$z9789811078583 000827211 830_0 $$aLecture notes in bioengineering. 000827211 852__ $$bebk 000827211 85640 $$3SpringerLink$$uhttps://univsouthin.idm.oclc.org/login?url=http://link.springer.com/10.1007/978-981-10-7859-0$$zOnline Access$$91397441.1 000827211 909CO $$ooai:library.usi.edu:827211$$pGLOBAL_SET 000827211 980__ $$aEBOOK 000827211 980__ $$aBIB 000827211 982__ $$aEbook 000827211 983__ $$aOnline 000827211 994__ $$a92$$bISE